CO2 INCUBATOR CB SERIES

INFORMATION

  • - Temperature range: room temperature plus 7 °C to 60 °C
  • - Humidity range: up to 95% RH
  • - Alternative O₂ control ranges: 0.2-20 vol. % O₂ or 10-95 vol. % O₂ (O, GO versions)
  • - Auto-sterilization with hot air at 180 °C
  • - Double-pan humidification system with condensation protection
  • - CO₂ gas-mixing jet with Venturi effect
  • - Hot-air sterilizable CO₂ sensor with infrared technology
  • - Display via color LCD monitor
  • - Lockable door handle
  • - Tightly-sealed inner door made of tempered safety glass
  • - Seamless, deep-drawn inner stainless steel chamber
  • - 2/3 perforated stainless steel shelves
  • - Units are stackable with stacking adapter
  • - Troubleshooting system with visual and audible alarms
  • - Computer interface: Ethernet
  • - Internal data recording and USB interface
  • - Zero-voltage alarm contact
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
CB 60 580 x 720 x 545 400 x 400 x 330 68 53
CB 170 680 x 870 x 715 560 x 600 x 505 95 170
CB 220 740 x 1070 x 715 560 x 750 x 500 132 210

CLASSIC INCUBATOR BD SERIES

  • - Temperature range: room temperature plus 5 °C to 100 °C
  • - APT.line™ preheating chamber technology
  • - Natural convection
  • - Adjustable exhaust air flap
  • - Controller with timer functions
  • - Inner door made of tempered safety glass
  • - 2 chrome-plated racks
  • - Units up to 115 liters are stackable
  • - Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm
  • - Computer interface: RS 422
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
BD 23 435 x 495 x 520 222 x 330 x 277 27 20
BD 400 1235 x 1025 x 765 1000 x 800 x 500 135 400

COOLING INCUBATOR KB SERIES

  • - Temperature range: -5 °C to 100 °C
  • - APT.line™ preheating chamber technology
  • - Up to 30% lower energy consumption compared to the previous model
  • - Cooling with compressor cooling unit
  • - Door heating system from 240 liters
  • - Adjustable fan speed
  • - Controller with time-segment and real-time programming
  • - Inner door made of tempered safety glass
  • - 2 stainless steel racks
  • - Units up to 115 liters are stackable
  • - Access port with silicone plug from 240 L
  • - Class 3.1 independent temperature safety device (DIN 12880) with visual and acoustic alarm
  • - Computer interface: Ethernet
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
KB 23 435 x 620 x 520 222 x 330 x 277 44 20
KB 53 635 x 835 x 580 400 x 400 x 330 78 53
KB 115 835 x 1025 x 650 600 x 480 x 400 106 115
KB 240 925 x 1465 x 800 650 x 785 x 485 171 247
KB 400 925 x 1950 x 805 650 x 1270 x 485 221 400
KB 720 1250 x 1925 x 885 970 x 1250 x 576 304 698

INCUBATOR

  • - 2 different classes according to performance characteristics: IN or INPLUS
  • - 8 different model options in the range of 32-749lt
  • - Temperature range ambient temperature +5 ... + 80°C
  • - Touch control
  • - Hygienic and easily cleanable stainless steel body
  • - Glass in the interior, 2 doors in stainless steel on the outside

DRYING AND HEATING CHAMBERS FED SERIES

  • - Temperature range: ambient temperature plus 10 °C to 300 °C
  • - Up to 30% lower energy consumption compared to conventional units on the market
  • - High temperature accuracy thanks to APT.line™ technology
  • - Adjustable fan speed
  • - Controller with LCD display and enhanced time functions
  • - Electromechanical control of the exhaust air flap
  • - 2 chrome-plated racks
  • - Units up to 115 liters are stackable
  • - Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • - Ergonomic handle design
  • - Ethernet interface
  • - USB port for recording data
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
FED 56 560 x 625 x 565 400 x 440 x 345 39 60
FED 115 710 x 735 x 605 550 x 550 x 385 54 116
FED 260 810 x 965 x 760 650 x 780 x 515 85 259
FED 720 1165 x 1590 x 870 1000 x 1300 x 570 166 741

CO2 INCUBATOR

  • - 3 different capacities: 108lt, 153lt, 246lt
  • - Temperature range +20 ... + 50°C
  • - Humidity range 88-97%
  • - CO2 range 0-20%
  • - CO2 measurement accuracy 0.1%
  • - Microprocessor control
  • - RS232 computer output
  • - Automatic sterilization mode

VACUUM ETUV VD SERIES

  • - Temperature range: room temperature plus 15 °C to 200 °C
  • - APT.line™ preheating chamber technology
  • - Controller with time-segment and real-time programming
  • - 2 aluminum expansion racks
  • - Inert gas connection
  • - Shatterproof, spring-mounted safety glass panel
  • - Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • - Computer interface: RS 422
  • - 2 relay outputs, 24 V DC (max. 0.4 A)
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
VD 23 515 x 665 x 500 285 x 285 x 295 63 23
VD 53 635 x 775 x 550 400 x 400 x 340 95 53
VD 115 740 x 900 x 670 506 x 506 x 460 153 115

COOLED INCUBATOR

  • - 5 different capacity options in the range of 53-749lt
  • - Temperature range -12 ... + 70°C
  • - High efficiency automatic ice melting system
  • - Glass in the interior, 2 doors in stainless steel on the outside
  • - Multifunctional programmability
  • - RS232 computer output

VACUUM ETUV VDL SERIES

  • - Temperature range: room temperature plus 15 °C to 200 °C
  • - ATEX compliance chamber's interior: Ex II -/3G c IIB T3-T1 Gc X
  • - APT.line™ preheating chamber technology
  • - Controller with time-segment and real-time programming
  • - 2 aluminum expansion racks
  • - Inert gas connection
  • - Shatterproof, spring-mounted safety glass panel
  • - Pressurized instrument panel with compressed air connection
  • - Pressure control device for heating activated < 125 mbar
  • - Flame protection gasket
  • - Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • - Computer interface: RS 422
Models Housing dimensions not incl. fittings and connections W x H x D [mm] Internal dimension W x H x D [mm] Net weight [kg] Interior volume [L]
VDL 23 515 x 665 x 500 285 x 285 x 295 63 23
VDL 53 635 x 775 x 550 400 x 400 x 340 95 53
VDL 115 740 x 900 x 670 506 x 506 x 460 153 115

VACUUM ETUV

  • - 3 different capacities: 29lt, 49lt, 101lt
  • - Temperature range +5 ... + 90°C
  • - Electronic controlled digital display
  • - Inner outer stainless body
  • - Stainless steel pipes and fittings
  • - RS232 computer output

DRY AIR STERILIZER - UN SERIES

  • - 2 different classes according to performance characteristics: UN or UNPLUS
  • - 9 different model options in the range of 30-1060lt
  • - Natural air circulation or ventilated air circulation
  • - Temperature range ambient temperature +5 ... + 300°C
  • - Working at 0.5°C accuracy
  • - With touch panel
  • - Stainless steel body